Search results for " Lenses"

showing 10 items of 190 documents

The utility of measuring tear film break-up time for prescribing contact lenses.

2017

Abstract Purpose To evaluate the clinical value of non-invasive keratograph tear film breakup time (NIKBUT) in the assessment of pre-corneal and pre-lens tear film quality for prescribing contact lenses (CLs). Methods Forty-six subjects aged 25.5 ± 4.3 (mean ± standard deviation) years were recruited. Visual acuity (VA), anterior eye health checks and NIKBUT were evaluated. On the following day, subjects were fitted with a daily Silicon Hydrogel (SiHy) CL in one eye and a Hydrogel (Hy) CL in the other. After four hours one material for both eyes was chosen based on a qualitative analysis which included VA, CL fitting and comfort. Information about the first and the mean NIKBUT was then cont…

0301 basic medicineAdultMalemedicine.medical_specialtyVisual acuityVisual Acuitylaw.invention03 medical and health sciencesYoung Adult0302 clinical medicineCLs upper limitslawOphthalmologyEye healthmedicineHumansmedicine.diagnostic_testBlinkingbusiness.industryCorneal TopographyQuality measurementGeneral MedicineTear film break-up timeCorneal topographyContact Lenses Hydrophiliceye diseasesLens (optics)Ophthalmology030104 developmental biologyPrescriptionsTears030221 ophthalmology & optometryTearsFemalemedicine.symptombusinessOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.

2016

Purpose To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). Methods Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest’s periphery. Results The maxi…

0301 basic medicineMaleScheimpflug principlelcsh:MedicineDiagnostic Techniques OphthalmologicalSeverity of Illness IndexMachine Learning0302 clinical medicineMedicine and Health Scienceslcsh:ScienceOptical PropertiesLens (Anatomy)PhysicsAged 80 and overMultidisciplinaryApplied MathematicsSimulation and ModelingOphthalmic ProceduresCataract SurgeryMiddle AgedOptical LensesOptical EquipmentPhysical SciencesEngineering and TechnologyFemaleAnatomyAlgorithmsResearch ArticleOpacityAdultDiagnostic Imagingmedicine.medical_specialtyComputer and Information SciencesScale (ratio)OpacityImaging TechniquesOcular AnatomyMaterials ScienceMaterial PropertiesEquipmentSurgical and Invasive Medical ProceduresImage AnalysisResearch and Analysis MethodsLens nucleusCataract03 medical and health sciencesMachine Learning AlgorithmsYoung AdultCataractsRegion of interestOcular SystemArtificial IntelligenceOphthalmologymedicineHumansAgedPixelCataractslcsh:RBiology and Life SciencesCorrectionLens Nucleus CrystallineLens Cortex Crystallinemedicine.diseaseIntensity (physics)Ophthalmology030104 developmental biologyLens DisordersCase-Control Studies030221 ophthalmology & optometryEyesCognitive Sciencelcsh:QHeadMathematicsNeurosciencePloS one
researchProduct

Effect of contact lens surface properties on comfort, tear stability and ocular physiology.

2018

Aim: Retrospective analysis of different contact lens wearing groups suggests lens surface lubricity is the main factor influencing contact lens comfort. However, the examined commercially available contact lenses differ in material and design as well as surface properties. Hence this study isolates the contribution of lens surface properties using an ultra-thin coating technology. Methods: Nineteen habitual contact lens wearers (21.6. ±. 1.7years) wore formofilcon B soft monthly disposable contact lenses with and without coating technology modified surface properties for a month each in a randomised double-masked cross-over study. Objective non-invasive: breakup time (NIKBUT), NIKBUT avera…

0301 basic medicineMalemedicine.medical_specialtyVisual analogue scaleSurface Propertieslaw.invention03 medical and health sciencesOcular physiologyYoung Adult0302 clinical medicineOpticsDouble-Blind MethodlawOphthalmologySurveys and QuestionnairesRetrospective analysisMedicineHumansCoefficient of frictionDisposable EquipmentRetrospective StudiesCross-Over Studiesbusiness.industryGeneral MedicineContact Lenses Hydrophiliceye diseasesLens (optics)Contact lensOphthalmology030104 developmental biologyPatient SatisfactionTears030221 ophthalmology & optometryFemalebusinessGrading scaleOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Accommodative response in various design soft contact lens wearers

2021

The progression of myopia in young adults due to inadequate accommodation is currently one of the global research challenges. Studies have demonstrated that multifocal contact lenses have a different effect on accommodative response. The aim of this study was to assess the accommodative lag using various design multifocal contact lenses at different working distances. The study was conducted on 10 emmetropic subjects aged 22â28 years. An open-field autorefractor PowerRef 3 was used to assess the response of eye accommodation to stimuli placed at a distance of 25 cm and 40 cm for subjects wearing monofocal and multifocal contact lenses. To determine the effectiveness of contact lens design f…

Accommodative responsegenetic structuresbusiness.industrynear additionScienceQGeneral Engineeringaccommodative lageye diseasesmultifocal contact lensesContact lensOptometryMedicinesense organsbusinessmyopia control.Proceedings of the Estonian Academy of Sciences
researchProduct

Myopia, the challenge of Ophthalmology and its worldwide “explosive epidemic”

2018

AdultAtropinePediatricsmedicine.medical_specialtyAdolescentExplosive materialContact LensesMEDLINE02 engineering and technology01 natural sciences010309 optics020210 optoelectronics & photonicsRisk Factors0103 physical sciencesMyopia0202 electrical engineering electronic engineering information engineeringmedicineHumansAge of OnsetChildLife StyleLightingLife stylebusiness.industryIncidenceIncidence (epidemiology)Disease progressionGeneral MedicineEyeglassesOphthalmic solutionsDisease ProgressionSunlightMorbidityOphthalmic SolutionsAge of onsetbusinessArchivos de la Sociedad Española de Oftalmología (English Edition)
researchProduct

Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography

2019

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…

AdultBiometryMaterials sciencegenetic structuresContact LensesTomography optical coherenceStatistics Nonparametriclaw.invention03 medical and health sciences0302 clinical medicineOpticslcsh:OphthalmologyOptical coherence tomographyLens thicknessAnterior Eye SegmentReference ValueslawmedicineHumansContact lensesAnalysis of VarianceCross-Over Studiesmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineAxial lengtheye diseasesContact lensLens (optics)Axial Length EyeOphthalmologylcsh:RE1-994Reference values030221 ophthalmology & optometrysense organsTomographybusinessTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.

2014

Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …

AdultDepth of focusPhakic Intraocular LensesVisual acuityCorneal Wavefront Aberrationgenetic structuresVisual AcuityDiagnostic Techniques OphthalmologicalPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineHumansComputer SimulationAdaptive opticsDioptreMathematicsWavefrontDepth PerceptionPupilPresbyopiaPresbyopiamedicine.diseaseeye diseasesSensory SystemsOphthalmologySpherical aberrationOptometrySurgerysense organsmedicine.symptomJournal of cataract and refractive surgery
researchProduct

Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.

2001

The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…

AdultGoldmann perimetryAdolescentmedia_common.quotation_subjectColour VisionEmmetropiaColorContact Lenses HydrophilicLuminanceSensory SystemsContact lensContrast SensitivityOphthalmologyContrast (vision)OptometryHumansVisual Field TestsVisual FieldsColor PerceptionLightingVision OcularOptometryMathematicsmedia_commonOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct